Potsdam Waste Water Treatment Plant, UF Section

 

Image 1
Image 2

Aquest UV Tech was approached by a contractor to supply a UV disinfection solution to treat the UF permeate discharged from Potsdam WWTP into the Milnerton lagoon, in Cape Town, South Africa. Because this is an ecologically sensitive water body, UV was the preferred solution specified by the consulting engineer in the tender document outlining the project requirements. The objective was to effectively disinfect and remove all pathogens in line with SANS special limit with faecal coliforms as the target microorganism for disinfection.

 

Design Criteria
UV Reactor Trojan UV Signa 2-Row
Application Waste water disinfection
Design Flowrate 65 MLD
UV Transmission 45 %
Disinfection Target 2 Faecal Coliform/100ml, 1 day Maximum
Validation Bioassy Validated, Full Compliance with USEPA/UVDGM/ NWRI and IUVA for high level applications
System Overview
Trojan UV Signa 2 Row Open Channel UV Reactor, fully automated, compact and modular with low lamp count high electrical efficiency.
Configuration Four UV Banks per channel, two channels, total of 8 banks
Lamp 1000W, LPHO Amalgam, Trojan UV Solo Lamp
Control Power Panel Microprocessor based monitors, digital interface with real time system status
Dose Pacing Automatic flow based program that dims lamps to conserve power under various water quality and flow conditions while maintaining disinfection dose
Sleeve cleaning Automatic, on line chemical and mechanical sleeve cleaning
UV Sensor UV Dose sensor monitors UV output to ensure UV Dose accuracy, lamp dimming from 100 to 30%