Belville Waste Water Treatment Plant, MBR Section

Image 1
Image 2

Belville Wastewater treatment plant contains 2 separate wastewater treatment lines, One which has a conventional activated sludge treatment chain for environmental discharge and another which uses MBR technology to treat effluent to reusable standard for industrial applications. Both systems contain Trojan UV disinfection systems which are managed and serviced by Aquest UV Tech. The MBR UV system was installed in 2013 and is still operational at present.

Design Criteria
UV Reactor Trojan UV 3000 Plus
Application Waste water disinfection
Design Flowrate 1667 m³/hr
UVT 65 %
TSS 2mg/l Monthly mean
Discharge limit 10 Faecal coliforms/100ml 30 day geometric mean
Validation USEPA, NWRI and IUVA bioassy validated dose
System Overview
Configuration Ten UV modules, 8 lamps per module, total 80 lamps
UV 3000Plus Highly flexible, reliable and robust open channel UV system with simplified maintenence designed specifically for waste water applications.
Lamp LPHO Amalgam lamps with high output and energy efficiency as a focus for compact design
ALC Automatic level control gate included
System control centre Microprocessor based monitors, digital interface with real time system status
Sleeve Wiping Automatic on line chemical and mechanical sleeve wiping system
UV Sensor UV Dose sensor monitors UV output to ensure UV Dose accuracy